Janitrol furnace - Viewed 3k times. 4. I have a Goodman Janitrol furnace and I am needing to add a C (common) wire, for the newer thermostats. I would like to avoid the substituting G for C, and just run an additional wire. I have read several post that suggest to use one of the Blue wires coming from the furnace transformer. I have attached pictures for reference.

 
The great outdoors. At mid-morning, the furnace-grade heat bounced off the hard clay. I couldn’t see myself living here. My husband, Rom Whitaker, though, was excited. His eyes wer.... Location of drake university

Residential Commercial Multi-Family. * Homeowner last name must be entered and verified to display complete limited warranty coverage. Want to access the warranty details on your Goodman HVAC system? Enter the product details and find the complete warranty information. So do not shut off the power once the T-Stat temp is reached and the burners shut down. (As A Test) Allow the cycle to remain (inducer fan running) for 15 minutes as part of the test. After 15 minutes and the fan is still running, adjust up the room temp to call for heat and note what happens. Nothing should happen.This item: OEM Upgraded Replacement for Janitrol Furnace Vent Air Pressure Switch B13701-33 . $27.51 $ 27. 51. Get it as soon as Thursday, Feb 15. Only 3 left in stock - order soon. Sold by North America HVAC and ships from Amazon Fulfillment. + Rebates & Incentives Product Registration. Goodman Manufacturing offers a range of affordable air conditioning, packaged units, heat pumps and gas furnaces for residential heating and cooling needs. Goodman Janitrol Amana Furnace Flame Sensor Sensing Rod 0130F00010 . Brand: KOB. 5.0 5.0 out of 5 stars 1 rating. Customers also viewed these products. Page 1 of 1 Start over Page 1 of 1 . Previous page. Upgraded Replacement fits Goodman Furnace Flame Sensor B11726-06. Calculated at Checkout. $16.24. Quantity: Select all. Add selected to cart. Description. OEM Janitrol Goodman Furnace Spark Flame Sensor B11726-01. You are looking at a Janitrol/Goodman/Amana Furnace Flame Sensor. The part # is B11726-01. Choose the right gas valve for you from our extensive selection of genuine Goodman, Amana, and Janitrol OEM replacement gas valves. Janitrol Repair Parts Janitrol HVAC Replacement Parts19 Dec 2018 ... Well, that would explain the resetting thermostat because the furnace was essentially shutting down and resetting itself…thus no power to the ...This B1859001S vent motor is a guaranteed genuine Goodman OEM replacement for several Goodman, Amana, and Janitrol units. All of our parts are shipped factory direct, giving you the assurance you need for a quality repair on your furnace, air conditioner, or other Goodman product. The B1859001S replaces outdated part numbers B1859001 and …This 0130F00010 flame sensor is a guaranteed genuine Goodman OEM replacement for several Goodman, Amana, and Janitrol units. All of our parts are shipped factory direct, giving you the assurance you need for a quality repair on your furnace, air conditioner, or other Goodman product. The 0130F00010 replaces outdated part numbers …name brand Janitrol (mainly used in aircraft so you know they are good) Model WH-100. 100,000 BTU input. 80,000 BTU output. Natural Gas. 120V single phase. Weight. 100 lbs. Dimensions.28 Sept 2010 ... Hey, Got a Janitrol forced air gas furnace Model 20-100 Serial number 4563 1 and can't find any indication of age.Mar 18, 2024 · Goodman is a reputable manufacturer offering reliable HVAC systems at lower costs. A member of the Dikin family, Goodman is a leading manufacturer of air conditioners, gas furnaces, and heat pumps ... The Consumer Product Safety Commission (CPSC) mandated a recall of 30,000 of the furnaces sold in California between 1982 and 1994. The furnaces were sold under a variety of different names, including Amana Company, American Standard Inc., Bard Manufacturing, the Trane Company and Goettl Air Conditioning Inc.Britain's Industrial Revolution likely accelerated the advancement of her great sailing ships as well. Economists have long seen the Industrial Revolution as a transformation of be...So do not shut off the power once the T-Stat temp is reached and the burners shut down. (As A Test) Allow the cycle to remain (inducer fan running) for 15 minutes as part of the test. After 15 minutes and the fan is still running, adjust up the room temp to call for heat and note what happens. Nothing should happen.Gas and Oil Home Heating Furnaces - Janitrol Furnace Won't Stay Lit - I have a 12 year old Janitrol Furnace that won't stay lit. The glow plug will light and the flame will burn for 5-7secs. This process will happen 3 times and then the furnace will cut off. I replaced the thermocouple (flame sensor) with a new Goodman.Great video of a bad flame sensor. What to look for when the flame sensor needs cleaned. No special tools are used to diagnos the malfunctioning flame sensor...1st: Select Part Type: 2nd: Enter Your Model Number or Part Number. Enter your units full model number or the part number needed below and we will locate the information you will need to place your order. Call or Text Message 1-914-294-2432 (EST) or 1-281-817-1088 (CST) or 1-509-293-9290 (PST) heat relays, sequencers, controls, fan and limit ... Find genuine Janitrol, Goodman and Amana HVAC repair parts for your furnace, air conditioner, heat exchanger and more. Shop with confidence and get fair pricing and prompt delivery from over 190 distribution centers nationwide. The duration of warranty coverage in Texas and Florida differs in some cases. At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A. Check out the 80% AFUE GMES80 Gas Furnace with Heavy-Duty Heat Exchanger Technology by Goodman - HVAC designed, engineered and assembled in the USA!My house has a Janitrol dependable 92 furnace. I would like to upgrade my thermostat, and the new one requires a "c wire" conection. I have an extra wire in the bundel that conects the t-stat to the furnace that i would like to conect, but when I opened the furnace there in no obvious "c wire" conection point. wondering if somone has a wire …Janitrol Repair Parts. Search By Equipment Type Here » Heat Exchangers. Condenser Fan Motors. Inducer/Vent Motors. Blower Motors. Gas Valves. Circuit …29 May 2022 ... ... Janitrol 4:40 - 2002 Payne Teardrop 4:53 - American Standards 5:19 - 2016 Payne Air Conditioner 5:33 - Payne & Guardian 5:55 - Two More ...31 Oct 2022 ... 33 Likes, TikTok video from The plumber (@theplumber13): “Came across a old 1960's janitrol furnace still kicking, this was part of a ...Find out if a single stage or two stage furnace is right for your home's heating needs. Get a free consultation to make the best choice. Expert Advice On Improving Your Home Videos...Oct 9, 2020 · Goodman gas furnaces have good AFUE ratings of between 80% and 98%, so they’re energy-efficient, although models with ratings between 80% and 90% would be more suited to warmer climates. Goodman is known for having some of the best warranties on the market. As long as you register within 60 days, Goodman gas furnaces have 10-year parts ... Calculated at Checkout. $16.24. Quantity: Select all. Add selected to cart. Description. OEM Janitrol Goodman Furnace Spark Flame Sensor B11726-01. You are looking at a Janitrol/Goodman/Amana Furnace Flame Sensor. The part # is B11726-01. Are you considering a Rheem furnace to replace your old, worn-out furnace? Here's what you can expect from Rheem with furnace costs. Expert Advice On Improving Your Home Videos Lat...This item: OEM Upgraded Replacement for Janitrol Furnace Vent Air Pressure Switch B13701-33 . $27.51 $ 27. 51. Get it as soon as Thursday, Feb 15. Only 3 left in stock - order soon. Sold by North America HVAC and ships from Amazon Fulfillment. +Slag Drainage and Afterburners - Slag drainage is needed on occasion when too much of the molten slag builds up at the bottom of the chamber. Learn about slag drainage. Advertiseme...This B1859001S vent motor is a guaranteed genuine Goodman OEM replacement for several Goodman, Amana, and Janitrol units. All of our parts are shipped factory direct, giving you the assurance you need for a quality repair on your furnace, air conditioner, or other Goodman product. The B1859001S replaces outdated part numbers B1859001 and …Find a Dealer. Find a Dealer. Enter Zip/Postal Code. Miles From Home. 1020304050. USE CURRENT LOCATION. SEARCH. SEARCH BY FILTER. FILTER BY.Janitrol Furnaces are made by Goodman Manufacturing Company. Goodman is known for producing energy efficient heating and cooling products for …This item: OEM Upgraded Replacement for Janitrol Furnace Vent Air Pressure Switch B13701-79 . $39.29 $ 39. 29. Get it Apr 1 - 2. In Stock. Ships from and sold by SupplyMount. + S1-02435261000 - York OEM Furnace Replacement Air Pressure Switch. $38.84 $ 38. 84. Only 1 left in stock - order soon.The Consumer Product Safety Commission (CPSC) mandated a recall of 30,000 of the furnaces sold in California between 1982 and 1994. The furnaces were sold under a variety of different names, including Amana Company, American Standard Inc., Bard Manufacturing, the Trane Company and Goettl Air Conditioning Inc.This is a guaranteed genuine Goodman OEM replacement circuit control board for several Goodman, Amana, and Janitrol units. All of our parts are shipped factory direct, giving you the assurance you need for a quality replacement on your furnace, air conditioning condensing unit, or other Goodman product. The B1809913S replaces …Starting on the upper right side of the diagram above: RC – Red: This wire provides 24 volt power from the furnace to the thermostat so that the thermostat can control air conditioning. R – Red: This wire serves the same purpose as the RC wire but for heating. Y – Yellow: Cooling Mode. This wire runs to the furnace control board which in turn …Janitrol Aero offers heating systems for general aviation and military aircraft. Find your product, shop for kits and upgrades, or visit the FAQ page for more information.Product page: http://goo.gl/sGcijDInformation on how to change out Goodman, Janitrol or Amana circuit board or control board provided by shortyshvac.com Give...Janitrol GDPX075-4B furnace parts - manufacturer-approved parts for a proper fit every time! We also have installation guides, diagrams and manuals to help you along the way! Can’t find your part? Contact us: +1-309-603-4777. Orders; Your models › ‹ Your models. Keep track of the models you own in your profile ...There are many reasons why your Janitrol furnace may have started to malfunction. If it’s not something big, like a fuse, then the next step is to replace the furnace. If this step is required, however, you may want to consider a heater repair service. HVAC technicians can fix most furnaces in an efficient and timely manner, and at a ...Janitrol furnace won't ignite. Has a new flame sensor. Igniter glows when trying to ignite but nothing happens except blower motor runs for 3--4 minutes and shuts off.Emergency! Your furnace pooped the bed and it couldn't have picked a worse time. What do you do? You save the day, Detroit DIY style! This video shows you ho...This 0130F00010 flame sensor is a guaranteed genuine Goodman OEM replacement for several Goodman, Amana, and Janitrol units. All of our parts are shipped factory direct, giving you the assurance you need for a quality repair on your furnace, air conditioner, or other Goodman product. The 0130F00010 replaces outdated part numbers … Janitrol HVAC Replacement Parts. Search for: Search. Search By Equipment Type Here. Forced-Air Furnace; Air Conditioning & Heat Pump Condensing Units; How to Determine Your Furnace BTU Size. Part of the series: Central Air Conditioning. To find the BTU size of a furnace, refer to the name plate or level pla...Janitrol GUS075-3 furnace parts - manufacturer-approved parts for a proper fit every time! We also have installation guides, diagrams and manuals to help you along the way! Can’t find your part? Contact us: +1-309-603-4777. Orders; Your models › ‹ Your models. Keep track of the models you own in your profile ...This item: WR Upgraded Replacement for Janitrol Furnace Gas Valve VR8215S1214 . $85.30 $ 85. 30. Get it Jan 30 - Feb 2. Only 10 left in stock - order soon. Ships from and sold by UR SUPPLY DIRECT. + Goodman CAP050450440RTP 45 + 5 uf/Mfd 370/440 VAC Replacement Round Dual Universal Capacitor.23 Jul 2018 ... Is your furnace blower motor not working and there is no air coming out of your vents? Perhaps your blower motor has burnt out and you need ...In the 1990s, Duo-Therm was one of the biggest manufacturers of furnaces for recreational vehicles. Today, many older recreational vehicles still use a Duo-Therm furnace to heat th...Janitrol Furnaces are made by Goodman Manufacturing Company. Goodman is known for producing energy efficient heating and cooling products for …Hit Ctrl+F and enter your model number for a quick search! This is a BRAND NEW Gas Furnace Condensate Trap. It is made for Goodman/Janitrol/Amana systems and the part # is 20171701. It works on MANY Goodman/Janitrol/Amana furnaces Thanks for looking and good! Please contact with any questions or other parts you m.Shut off the gas. Turn the gas valve to the “Off” position. Give the appliance at least five minutes to cool down and let any residual gas clear out. After cleaning or replacing the thermocouple, you will want to test the appliance by relighting the pilot. Turn the gas regulator valve to the “pilot” position.Find many great new & used options and get the best deals for Packard Starlite 1121 Furnace Hot Surface IGNITOR for Goodman Janitrol B1401018s at the best online prices at eBay! Free shipping for many products!Universal Hot Surface Gas Furnace HVAC Round Igniter Kit SIG1000By utilizing one of the two brackets included, the SIG1000 is designed to replace over 100 original part number... Large bracket used to replace 41-403, 41-407, 41-409• Small bracket used to replace 41-402, 41-405, 41-410• Easy installation Read More Read LessThe B13701-54 Goodman Janitrol Furnace Limit Rollout Switch is used in the following Goodman furnace models: GMP, GMPE, GMPH, GMP (50Hz), GPD, GMPN, GSMS, GSM (All), PGB024050-1 thru PGB060150-4, PGJ024050-1 thru PGB048100-1. We have a more comprehensive list of furnaces this rollout switch is used on below.How to Determine Your Furnace BTU Size. Part of the series: Central Air Conditioning. To find the BTU size of a furnace, refer to the name plate or level pla...Goodman Global. Goodman Manufacturing is an American company operating as an independent subsidiary [1] [2] of Daikin Group, the world's largest manufacturer of heating, ventilation and air conditioning products and systems. The company, founded in 1975 and based in Waller, Texas, manufactures residential heating and cooling systems. [3]Goodman Furnace Warranty. Goodman is known for having one of the best furnace warranties for their natural gas furnaces and other HVAC systems. You must register your new gas furnace within the predetermined time frame of 60 days to avail this. Their furnace warranty includes: 10 Year Parts Limited WarrantyNov 23, 2021 · Amana has a great selection of furnace units while Rheem and Goodman offer furnace options that are budget friendly and reliable. That said, all five brands have some of the best reputations and produce efficient units that fit multiple lifestyles. Mary Henn, MFA is an Associate Shopping Editor at Family Handyman. 17 Jul 2013 ... Furnace repair. Customer has a 10year old janitrol furnace. Model GMNT100-4. Furnace will not light. Install a new hot surface ignitor. If ...Feb 1, 2024 · Editors’ Choice: The 60,000 to 120,000 BTU-per-hour heating input and its 98 percent efficiency make this Goodman GCVM97 gas furnace (available at Goodman) a great choice for most homes. Solar flares and their effect on electronics are explained in this article. Learn about solar flares. Advertisement A song written by Hy Zaret and Lou Singer, later popularized by ... With over $100M investment in new manufacturing equipment, Goodman is positioned to provide high-quality products for years to come. For over three decades, thousands and thousands of HVAC pros have recognized Goodman’s commitment to quality products. In fact, we are so committed that we built out our 4.2 million square foot manufacturing ... Frequently bought together. This item: LTD Goodman Janitrol Control Circuit Board Panel B18099-13. $15900. +. Robertshaw 41-418 Furnace Ignitor Janitrol Goodman B1401018S Modine 5H75032A. $2368. +. OEM Upgraded Replacement for Goodman Furnace Vent Air Pressure Switch B13701-42. $1551.Find genuine Janitrol, Goodman and Amana HVAC repair parts for your furnace, heat exchanger, condenser and more. Shop with confidence and get fair pricing and timely delivery from …Goodman Global. Goodman Manufacturing is an American company operating as an independent subsidiary [1] [2] of Daikin Group, the world's largest manufacturer of heating, ventilation and air conditioning products and systems. The company, founded in 1975 and based in Waller, Texas, manufactures residential heating and cooling systems. [3]How does natural gas drilling work? Keep reading to learn about natural gas and how natural gas drilling works. Advertisement When you switch on your furnace or turn on your gas st... Janitrol HVAC Replacement Parts. Search for: Search. Search By Equipment Type Here. Forced-Air Furnace; Air Conditioning & Heat Pump Condensing Units; 22 Jan 2015 ... This Janitrol furnace is one of the clam shell exchangers from the mid 1990s that were notorious for failure.Find a Dealer. Find a Dealer. Enter Zip/Postal Code. Miles From Home. 1020304050. USE CURRENT LOCATION. SEARCH. SEARCH BY FILTER. FILTER BY.The installation cost for a Lennox gas furnace can fluctuate between $2,870 and $8,250, dependent on the chosen model. Lennox furnaces come in a variety of energy efficiency levels, with an AFUE rating ranging from 80% up to 95%, providing options to suit different budgetary and efficiency requirements. Best Feature.This is a BRAND NEW Furnace Blower Relay with a 24 volt coil. It is designed to replace Goodman/Amana/Janitrol part #s B1370737, B13707-37, B13123-01, & B1312301. This relay has five spades (wiring terminals). It is a heavy duty relay rated for up toTo find the size of a Janitrol unit, go to What size in tons is a Janitrol air conditioner or heat pump from the model number? And to figure out what all … Goodman Global. Goodman Manufacturing is an American company operating as an independent subsidiary [1] [2] of Daikin Group, the world's largest manufacturer of heating, ventilation and air conditioning products and systems. The company, founded in 1975 and based in Waller, Texas, manufactures residential heating and cooling systems. [3] This is a BRAND NEW Furnace Blower Relay with a 24 volt coil. It is designed to replace Goodman/Amana/Janitrol part #s B1370737, B13707-37, B13123-01, & B1312301. This relay has five spades (wiring terminals). It is a heavy duty relay rated for up to Air Conditioning Condensing Unit Gas/Electric Package Unit Forced-Air Furnace WH Equpment. ... Janitrol HVAC Replacement Parts. Search for: Search. Air Conditioning Condensing Unit Gas/Electric Package Unit Forced-Air Furnace WH Equpment. ... Janitrol HVAC Replacement Parts. Search for: Search. Limit Switches | Janitrol Repair Parts Goodman Limit Switches: 1370901S 1370902S 1370903S 1370905S 1370906S 1370908S 1370909S 1370910S 1370911S 1370912S 1370914S 1370915S 1370916S ... Forced-Air Furnace; Air Conditioning & Heat Pump Condensing Units; Gas/Electric Package Unit; WH Equipment; Heat Exchangers; …It is a direct replacement for Goodman/Janitrol/Amana part #s B1401015S, B1401015, & B14010-15. Simply unplug yours, and plug this one in. The wire leads measure 5-1/2" long, with connector.23 Jul 2018 ... Is your furnace blower motor not working and there is no air coming out of your vents? Perhaps your blower motor has burnt out and you need ...GMP100-3 Parts List: Blower Motor — B1340021S, Goodman/Janitrol, 1/3HP, Direct Drive Vent/Inducer Motor — B1859005 / B1859005S, Goodman/Janitrol . ... Circuit Board — B1809913S Goodman/Janitrol Furnace Control Board $ 204.99 $ 184.99 Add to cart . Gas Valve — 0151M00013S / B1282628, Single Stage $ 114.27 $ 102.84 …Gas and Oil Home Heating Furnaces - janitrol furnace burners won't light - I have a janitrol gas furnace. it has 3 burners. when I go to fire it up the burner on the right ignites for about 10 seconds then goes out. a minute or 2 later it repeats the same sequence. the flame sensor is over by the left burner and I haveFOR JANITROL FURNACE EXPERT: I have a Janitrol gas furnace for the 1st floor of a 2 story rental house. I have had licensed H&A contractors out for 3 straight days to try to find out why it is not wor … read more- Furance. Updated: Feb 10, 2023. error codes guide Janitrol. Janitrol Furnace Troubleshooting. There is a list of possible breakdowns or operating problems …Gas Furnaces, Residential Unitary, HVAC Equipment, including 2" CONCENTRIC VENT TERMINAL KIT, 80% AFUE Upflow/Horizontal Gas Furnace GM9S80..0:00 / 5:42. Janitrol furnace bad flame sensor DIY. themrhelperguy. 21.4K subscribers. Subscribed. 29. Share. 8.1K views 7 years ago. Great video of …In this episode of Repair and Replace, Vance shows how to replace the draft inducer blower in a gas furnace. The draft inducer fan pulls air into the burner....GMPN080-4 Parts List: Blower Motor — B1340020S, Goodman/Janitrol, 1/2HP, 1075 RPM, 3 Speed Vent/Inducer Motor – B2833001S, Goodman/Janitrol ... Circuit Board — B1809913S Goodman/Janitrol Furnace Control Board $ 204.99 $ 184.99 Add to cart . Gas Valve — 0151M00013S / B1282628, Goodman/Janitrol, Single StageMar 18, 2024 · Goodman is a reputable manufacturer offering reliable HVAC systems at lower costs. A member of the Dikin family, Goodman is a leading manufacturer of air conditioners, gas furnaces, and heat pumps ...

Goodman/Janitrol/GMC. UH-150(BK, DU) and UH-200(BK,DU) Heil/Tempstar. NT005150BKA1 and NT005200BKA1. ... Consumers who own recalled furnaces should call their dealers to arrange installation of a free recall upgrade kit. For more information, consumers can call Excell Comfort Systems (which bought the furnace portion of the …. Marbles game online

janitrol furnace

22 Jan 2015 ... This Janitrol furnace is one of the clam shell exchangers from the mid 1990s that were notorious for failure.This is a guaranteed genuine Goodman OEM replacement circuit control board for several Goodman, Amana, and Janitrol units. All of our parts are shipped factory direct, giving you the assurance you need for a quality replacement on your furnace, air conditioning condensing unit, or other Goodman product. Replaces Circuit Board for Model Numbers:1. Turn Off the Gas. Safety should always be the top priority when dealing with any heating system. Before attempting to light the pilot on your old …Find official Janitrol furnace parts for your heating and cooling system. Shop by model, browse the most common parts that need replacing, and get …Find out if a single stage or two stage furnace is right for your home's heating needs. Get a free consultation to make the best choice. Expert Advice On Improving Your Home Videos...This item: OEM Upgraded Replacement for Janitrol Furnace Hot Surface Ignitor/Igniter 201657-03 . $51.95 $ 51. 95. Get it Mar 11 - 12. In Stock. Ships from and sold by North America HVAC. + OEM 47-22861-01 Replacement Furnace Limit Switch L350 Compatible with Rheem #47-22861-01. $12.99 $ 12. 99.The great outdoors. At mid-morning, the furnace-grade heat bounced off the hard clay. I couldn’t see myself living here. My husband, Rom Whitaker, though, was excited. His eyes wer...19 Jan 2023 ... Sacramento HVAC - Troubleshooting a Janitrol Furnace and the Slightly Cluttered Attic. Fox Family Heating and Air Conditioning•20K views · 9:25.1982 - Acquired Janitrol and began manufacturing central air conditioning systems. 1986 - Expanded product offerings to include gas heating products. 1997 ... (now Whirlpool), but retained the furnace and air conditioner division including Amana branded HVAC systems. 2004 - Goodman acquired by Apollo Managment, a private equity firm.So do not shut off the power once the T-Stat temp is reached and the burners shut down. (As A Test) Allow the cycle to remain (inducer fan running) for 15 minutes as part of the test. After 15 minutes and the fan is still running, adjust up the room temp to call for heat and note what happens. Nothing should happen.The installation cost for a Lennox gas furnace can fluctuate between $2,870 and $8,250, dependent on the chosen model. Lennox furnaces come in a variety of energy efficiency levels, with an AFUE rating ranging from 80% up to 95%, providing options to suit different budgetary and efficiency requirements. Best Feature.I'm trying to install a Nest power connector to my Janitrol furnace. The ignition controller module is 13707-24 1003-300 and the color code on the wire is weird.10. The Furnace Leaks when AC is Running. Water condenses on the evaporator coil in your furnace, and if it leaks onto the floor, the issue is most likely a clogged drain pan or drain line, an issue covered in our AC Troubleshooting Guide. 11. The Air Coming from the Furnace Smells Bad.Most Janitrol Aero I-Series, B-Series and CD-Series heaters require 6.5­–8 PSI (except for turbine aircraft, which are 100–105 PSI). Original South Wind 8240, …With busy lives, it's easy to let chores around the house slip through the cracks. Corral the details into this customized planner to help you track everything from daily chores to... With over $100M investment in new manufacturing equipment, Goodman is positioned to provide high-quality products for years to come. For over three decades, thousands and thousands of HVAC pros have recognized Goodman’s commitment to quality products. In fact, we are so committed that we built out our 4.2 million square foot manufacturing ... This is a Brand New OEM Furnace Control Circuit Board ; Top Quality OEM Replacement Part! Customers also viewed these products. Page 1 of 1 Start over Page 1 of 1 . Previous page. OEM Upgraded Replacement for Goodman Furnace Vent Air Pressure Switch B13701-42.In this episode of Repair and Replace, Vance shows how to relight the pilot light, in a standing pilot furnace. If your pilot light goes out, all you need to....

Popular Topics